OEM/ODM Laboratory preparation instruments

Home / Products / Laboratory Instruments / Laboratory preparation instruments
Shanghai Qiujing Biochemical Reagent & Instrument Co., Ltd. is a pioneering enterprise dedicated to the research, development, and production of precision micropipettes. As a trailblazer in this field in China and a forerunner in replacing imported products with domestically manufactured alternatives, the company has been deeply committed to the laboratory instrument sector since its brand was established in 1988. The brand officially completed the registration of its Chinese and English trademarks in 1992. Driven by a persistent pursuit of technological innovation, the company has continuously advanced its production capabilities, mastering advanced manufacturing and testing technologies, overcoming multiple industry technical challenges, and securing a number of technical patents that provide a solid foundation for product quality.
Shanghai Qiujing Biochemical Reagent & Instrument Co., Ltd. is a China Laboratory preparation instruments Manufacturer and OEM/ODM Laboratory preparation instruments Factory. At the same time, the enterprise has established a comprehensive quality management system and has successfully obtained CE and ISO 13485 quality system certifications. Its sales and service network extensively covers the entire country, while its products are also exported to overseas markets, earning recognition from both domestic and international customers.
ABOUT QIUJING

BELIEVE IN OUR STRENGTH

Shanghai Qiujing Biochemical Reagent & Instrument Co., Ltd.
Shanghai Qiujing Biochemical Reagent & Instrument Co., Ltd.
Shanghai Qiujing Biochemical Reagent & Instrument Co., Ltd.
  • Shanghai Qiujing Biochemical Reagent & Instrument Co., Ltd.
    1988Year

    Founded In

  • Shanghai Qiujing Biochemical Reagent & Instrument Co., Ltd.
    35Year

    Industry Experience

  • Shanghai Qiujing Biochemical Reagent & Instrument Co., Ltd.
    3000㎡

    Factory Area

  • Shanghai Qiujing Biochemical Reagent & Instrument Co., Ltd.
    15+

    Core Products

EXPLORE WHAT'S NEW
Keeping you connected with laboratory innovation
  • 2026/11/06
    Industry News
    Laboratory Equipment Buying Guide: Workflow First, Specifications Second
    The first equipment list in a new laboratory is usually written backwards. Someone opens a vendor catalogue at page one and starts ticking boxes; six months later the pipettes do not fit the plates, the centrifuge cannot spin the tubes the protocol specifies, and a slice of the budget is sitting in
  • 2026/10/30
    Industry News
    Analytical Instruments Manufacturer: Specs, Data Path and Buying Checks
    A hospital laboratory in Southeast Asia shortlists three benchtop spectrophotometers. All three cover the required wavelength range. Only one can send a result straight to a printer without a laptop sitting in between. That single detail, not the quotation total, decides the order. When you evaluat
  • 2026/10/23
    Industry News
    Analytical Instruments Factory: How to Source Calibrated Lab Analyzers
    Nine times out of ten, a lab instrument purchase starts with a price comparison and ends with a service problem. If you are sourcing analytical instruments from a factory, the first thing worth checking is not the quotation but the calibration file behind the sample unit. A visible spectrophotomete
Certificate Of Honor
  • Certificate of EU Medical Device Notification
  • Certificate of EU Medical Device Notification
  • Certificate
  • Certificate
  • Certificate
  • Certificate of Export Sales for Medical Devices
  • Class I Medical Device Production Record Certificate
Message Feedback
Laboratory preparation instruments Industry knowledge

Shanghai Qiujing Biochemical Reagent & Instrument Co., Ltd. builds the benchtop hardware that carries a sample from raw material to a measured result. Our brand was established in 1988, and Qiujing has developed precision micropipettes, mixers, centrifuges, baths and preparation instruments for laboratories working in industrial R&D and quality control, food and environmental testing, life science research, medical testing and biopharmaceutical production.

Sample preparation converts an as-received specimen into a state an analytical method can accept: digestion, homogenization, grinding, filtration, drying and temperature-controlled incubation. Our preparation range covers the thermal, agitation and separation side of that workflow. We supply it as a China laboratory preparation instruments manufacturer with OEM/ODM engineering, CE and ISO 13485 quality systems, and an established export business serving overseas laboratory distributors and end users.

What the Laboratory Preparation Range Covers

The current Laboratory preparation instruments manufacturer family is anchored by the Qiujing YKJ-16 intelligent digester, a benchtop unit with a colour LCD interface, adjustable temperature and time parameters and thermal insulation built for a stable hold step. Around it, we supply the companion equipment that a preparation bench needs, so a single order can equip a complete workflow rather than a single station.

  • Digestion and thermal preparation: intelligent digester with programmable temperature and time, insulation for stable holding.
  • Heating and incubation: water baths and metal (dry block) baths for reagent warming, thawing and tube-scale incubation.
  • Agitation: vortex mixers, magnetic stirrers and overhead electric mixers for resuspension, dissolution and blending.
  • Separation: the Laboratory Centrifuge Series for phase separation, clarification and pellet recovery.
  • Transfer and dosing: micropipettes, macropipettes and automatic micro liquid dispensers.
  • Measurement checks: balances, pH meters and photometers from our wider Laboratory Instruments portfolio.
  • Consumables: pipette tips with low retention, racked or bagged formats.

Product Range and Application Matching

Product family Role in sample preparation Main selection variables
YKJ-16 intelligent digester Temperature- and time-controlled digestion of solid and semi-solid samples Programme steps, vessel format, hold stability, fume handling
Water baths Reagent warming, thawing, water-bath incubation Bath volume, temperature range, uniformity, lid and rack type
Metal baths Dry-block digestion and incubation of small tubes Block format, well count, tube diameter, heating rate
Vortex, magnetic stirrer and electric mixer series Resuspension, homogenization, dissolution of powders and viscous samples Speed range, orbit or stirrer diameter, sample volume, viscosity, gasket wear
Laboratory Centrifuge Series Clarification, phase separation, cell and precipitate recovery Rotor and bucket type, relative centrifugal force, tube format, run time
Micropipettes, macropipettes, automatic micro liquid dispenser Reagent addition, aliquotting, serial dilution before analysis Volume range, single or multichannel, accuracy and repeatability, autoclavability
Balances, pH meters, photometers Gravimetric preparation and verification of prepared solutions Readability, capacity, measuring range, resolution, calibration routine
Pipette tips and consumables Contamination-controlled transfer of samples and reagents Filtered or unfiltered, racked or bagged, low retention, nuclease-free status

The YKJ-16 Intelligent Digester in a Working Method

The Qiujing YKJ-16 is built around the two parameters that decide digestion reproducibility: temperature and time. Both are set on the colour LCD interface, so a validated programme can be repeated by different operators without manual intervention. Insulation around the working zone holds the set point through the digestion step instead of letting the block cool while vessels are being loaded.

We configure the unit around the digestion chemistry that will actually be run. Acid digestion of food, feed or environmental solids, ambient-pressure wet digestion before spectrometric measurement and temperature-controlled extraction each place different demands on vessel selection, loading pattern and programme length. Share the digest volume, acid or solvent system and the target hold time, and we will match the instrument configuration and vessel set to the method. Full model data is listed on the Qiujing YKJ-16 intelligent digester specification sheet.

Preparation bench pairing: a digester is usually ordered together with a Laboratory Water Baths Series unit for cooling and post-digestion temperature steps, a centrifuge for clarification, and pipetting equipment for volumetric make-up. We quote these as one configuration when the workflow is known.

Application Fit Across Laboratory Types

Preparation equipment is used differently in each environment we serve, and the delivered configuration follows that difference.

  • Industrial R&D and quality control: repeatable digestion and homogenization of incoming raw materials, intermediates and finished goods, with instrument-to-instrument consistency across shift work.
  • Food and environmental testing: batch digestion of solids and semi-solids for metals and contaminant analysis, plus sample clean-up before instrumental measurement.
  • Medical testing and clinical laboratories: controlled thawing, incubation and separation steps where procedure stability matters more than throughput.
  • Biotechnology and pharmaceutical: method repeatability and traceable documentation through development, scale-up and routine quality control.
  • Universities and research institutes: multi-discipline benches needing a compact set of thermal, mixing and separation instruments.

Critical Specifications We Confirm Before Build

Digestion and bath performance is governed by a small set of variables. We confirm these against the method rather than against a catalogue number alone.

  • Temperature range and set-point resolution against the digestion or incubation chemistry.
  • Hold stability and recovery time when vessels are loaded or the lid is opened.
  • Programme segmentation — ramp, hold and cooling steps for multi-stage methods.
  • Vessel and block format, including digest tube diameter, working volume and headspace.
  • Batch capacity relative to daily sample count and the number of runs per working day.
  • Repeatability of the temperature and time parameters across consecutive runs.
  • Material compatibility of wetted parts with the acid, solvent or reagent in use.

Controls, Utilities, Installation and Operator Safety

Preparation instruments are bench units, so integration work is mostly electrical and environmental. We size the power configuration to the destination market, and our benchtop equipment is engineered around wide-range switching supply designs — the Qiujing Whirlwind mini centrifuge series, for example, runs from AC100–240 V / 50–60 Hz input, and we apply the same approach to preparation hardware where the market requires it.

Installation planning covers bench footprint and clearances, ventilation for acid digestion work, fume-extraction expectations at the customer site, and a stable level surface for units with moving vessels. Operator-facing controls are kept simple: parameter entry on the LCD, an unambiguous run state, and physical separation between the hot working zone and the operator's hands. We supply operating and safety instructions with each unit, and our technical team covers operation guidance and troubleshooting during after-sales support.

Quality System, Acceptance and Compliance Evidence

Qiujing works under a documented quality management system with CE and ISO 13485 certification, and holds EU medical device notification, medical device export sales and Class I medical device production record certificates. Our in-house test laboratory supports development and finished-product verification, and we hold technical patents covering product design work.

Production is controlled at three checkpoints — incoming raw material inspection, in-process testing and finished-product inspection — with the results recorded against the order. For preparation instruments, acceptance at the customer site normally covers visual inspection and packing integrity, an insulation and earth-continuity check, a no-load run to confirm control response, and a repeatability run on the agreed set point using the customer's own vessels. We supply the documentation set needed for that acceptance before shipment.

Information We Use to Configure Your Solution

A preparation instrument proposal is only as good as the process detail behind it. We use the following project inputs to build the configuration, the bill of auxiliary items and the quotation.

  • Sample matrix and typical sample mass or volume per digest.
  • Full preparation method — ramp, hold and cooling steps, reagent or acid system, target temperature and time.
  • Vessel type and format already used in the laboratory, or an open specification if new glassware is acceptable.
  • Daily and peak sample counts, plus the working pattern of the bench.
  • Destination market, supply voltage and frequency, and plug standard.
  • Preferred control interface, display language and labelling.
  • OEM/ODM requirements: enclosure appearance, branding, packaging design and specification adjustments.
  • Documentation set, training needs, spare-parts holding and delivery destination.

Configuration, Customisation, Delivery and Service

We run OEM/ODM projects from requirement consultation through solution and sample confirmation, precision manufacturing and global delivery, with after-sales support covering product consultation, operation guidance and troubleshooting. Customisation covers product design, specification adjustment, appearance and packaging — relevant to distributors building a local brand and to end users needing a bench that matches an existing method.

Standard production lead time is 10 working days; the schedule for a configured or customised unit is confirmed once the specification is frozen. Units ship with operating instructions and the agreed test records, packed for international transport, and spare parts and consumable accessories are quoted with the instrument so that the bench stays serviceable after commissioning.

Frequently Asked Questions

What does Qiujing manufacture in the preparation instrument category?

We manufacture and supply the intelligent YKJ-16 digester together with the companion equipment a preparation bench needs: water baths, metal baths, vortex and magnetic mixers, electric mixers, centrifuges, balances, pH meters, photometers and the pipetting and consumable items used before and after the thermal step.

Can the digester be matched to an existing digestion method?

Yes. Send the sample matrix, acid or solvent system, vessel format, target temperature and hold time, and we will confirm the programme structure and vessel set. Where a method uses several temperature stages, the programme is segmented accordingly and the customer's own vessel geometry is taken into account when configuring the working zone.

Do you support OEM/ODM customisation on preparation instruments?

We do. OEM/ODM scope includes specification adjustment, appearance and enclosure customisation, branding and packaging design, supported by our R&D team. Projects start from drawings, samples or a written functional requirement, and we confirm the specification on a sample before formal production.

What quality evidence is issued with an order?

Orders are produced under our CE and ISO 13485 certified quality system with incoming material inspection, in-process testing and finished-product inspection recorded against the build. Certificates covering EU medical device notification, medical device export sales and Class I medical device production records are held by the company, and the relevant test documentation accompanies the shipment.

Are samples available, and how long does delivery take?

Samples are available for performance and compatibility verification before bulk orders. Standard production lead time is 10 working days; configured or customised units are scheduled after specification confirmation, and the delivery window for a specific model, quantity and destination is stated in the quotation.

What information do you need to quote a preparation package?

The preparation method and sample matrix, expected daily throughput, vessel format, supply voltage for the destination market, any OEM/ODM requirements and the documentation or training scope needed. With those inputs we return a configuration covering main unit, auxiliary bench equipment, consumables and spare parts in a single proposal.